Optical cable
Outdoor directly buried LSZH flame retardant optical cable GYXTZW
GYXTZW
GYXTZW flame-retardant optical cable, flame-retardant, rat proof, 10 gigabit high-speed broadband
Quantity

                                                 

 
Technicalspecifications of optical cable

Cable Fiber Number 

4-12 

Optical fiber type 

G.652D 

Design structure (stiffener + loose casing 

and filling) 

1 

Stiffening member 

Materials 

Phosphating steel wire 

Diameter±0.05mm 

0.7 

loose tube 

Materials 

PBT 

Diameter±0.06mm 

2.15 

Thickness(±0.03mm 

0.30 

Each tube some 

12 

The armoured layer 

Materials 

Plastic coated  steel belt 

Thickness+0.03mm 

0.20 

Outer sheath 

Materials 

LSZH 

Thickness±0.2mm 

1.8±0.05 

Color 

Black 

Cable size mm 

7.0±0.05 

Fiber optic cable net weight±10kg/km 

65KG/KM 

Allowable tensile strength (N) 

600 

Flattening force is allowed (N/100mm) 

600 

Application 

Overheadmonitoring 

Attenuation 

1310nm 

0.36dB/ km 

1550nm 

0.22dB/ km 

bending 

radius 

 Dynamic 

25.0D 

Static 

12.5D 

  temperature range 

℃) 

 Installation temperature 

-20+60 

Transportation & Storage 

-40+70 

Running temperature 

-40+70 

 Optical chromatography

number

1

2

3

4

5

6

color

blue

Orange

green

brown

gray

white

number

7

8

9

10

11

12

color

red

black

yellow

violet

pink

turquoise

 

Loose tube chromatography 

number

1

Color

White

 

Fiber properties (ITU-TG.652.D)

Item 

Unit 

Parameter 

G.652D 

Mode field diameter 

1310nm 

m 

9.2± 0.4 

1550nm 

m 

10.4  ± 0.5 

Cladding diameter 

m 

125± 1 

Cladding non-circularity 

% 

1 

Core/cladding concentricity error 

m 

0.6 

Coating diameter 

m 

242± 7 

Coating/cladding concentricity error 

m 

12 

Cable cut-off wavelengt 

nm 

1260 

Attenuation Coefficient 

1310nm 

dB/km 

0.36 

1550nm 

dB/km 

0.22 

Proof stress leve 

kpsi 

100 

    Other parametersmeet standards ITU-T G.652 

Main mechanical properties and environment tests

number 

item 

test mode 

acceptance requirements 

1 

Stretch 

IEC 60794-1-2-E1 

- Load: 600 N(long term) G (short-term) 

When G is less than 1500N, 

the cable load should be 1500N; 

Under long-term tension load: 

- The optical fiber has no obvious strain 

-Noobvious additional 

when G is between 1500 and 3000N, 

the cable load should be 1500N; 

when G is greater than 3000N, 

the cable load should be 3000N. 

- Subject length: 50 m 

- Load duration: 1 minute 

attenuation 

Short-term tension load: 

- Additional attenuation:     0.1dB After the test is completed: 

-Nosignificant residual additional attenuation 

- No obvious residual fiber strain 

-No broken fiberand visible cracking of sheath 

- Cable residual strain:      0.08% 

2 

flattening IEC 60794-1-2-E3 

 

- Load: 

300 N (long term) 1000 N (short term) 

- Load duration: 1 minute 

Under long-term flattening load: 

-Noobvious additional attenuation 

Short-term flattening load: 

- Additional attenuation:     0.1dB After the test is completed: 

-Nosignificant residual additional attenuation 

-No broken fiberand visible cracking of sheath 

3 

impact  IEC 60794-1-E4 

 

- Impact points: 5 

- Impact times per point :1 

- Impact energy: 4.5 N·m 

After the test is completed: 

-Nosignificant residual additional attenuation 

-No broken fiberand visible cracking of sheath 

4 

  alternating bending 

IEC 60794-1-2-E6 

 

- Core shaftradius: 20 timescable diameter 

- Load: 15kg 

- Subject length: 1 m 

- Bending rate: 2 seconds/time 

- Bending times: 30 times   - Bending Angle: ±90  

After the test is completed: 

-Nosignificant residual additional attenuation 

-No broken fiberand visible cracking of sheath 

5 

reverse  IEC 60794-1-E7 

- Subject length: 1 m 

- Load: 15kg 

- Torsion Angle: ±180° 

- Number of twists: 10 times 

After the test is completed: 

-Nosignificant residual additional attenuation 

-No broken fiberand visible cracking of sheath 

6 

infiltration test IEC 60794-1-F5B 

- Water column height: 1 m 

- Sample length: 3 m 

- Test duration: 24 hours 

  

There is no water seepage 

7 

High and low temperature cycle test 

IEC 60794-1-F1 

 

- Temperature step: 

+20℃→-40 +70℃→+20  

- Duration of each temperature point: 12 hours 

- Number of cycles: 2 

-40+70  Additional attenuation   0.1 dB/km@1550 nm 

After the test is completed: 

-Nosignificant residual additional attenuation 

-No broken fiberand visible cracking of sheath 

8 

Drip test  IEC 60794-1-E14 

- Sample length: 30 cm 

- Temperature:70°C -2°C 

- Test time: 24 hours 

   No drip 

Sheath tag

Theinitialnumber of lengths ordered for any coil shall begin with zero metres. The accuracy of length marker measurement should be controlled within 

±1%.Fiber optic cable printing should have the following content.

 A. Name of manufacturer

  1. Cable type
  2. Yearand month of manufacture
  3. each meter of length marked along the cable

Plate with

Optical fiber some 

Wooden tray diameter 

Wooden platewidth 

Long 

packaging 

4-12 

700MM 

650MM 

3000(m) 

Plastic coated Steel belt