Fiber Optic Cable
GYFXTY Outdoor Single Mode Nonmetal Flat Fiber Optic Cable
GYFXTY
1.250μm single-mode fiber is located in the loose sleeve made of PBT plastic. The gap in the loose sleeve tube is filled with a contact paste compound and located in the center of the whole cable.
2. Multiple metal stiffeners and yarns are wound around the center tube with appropriate pitch, and a waterproof material is applied at the same time.
3. Polyethylene sheath or other materials such as low smoke halogen-free polyolefin are tightly coated around the reinforcement.
Quantity

                                                              


 

Technicalindex of optical cable
 

Fiber core number 

1 

2 

4 

8 

12 

Typeof optical fiber 

G.652D 

Design (loose casing and filling) 

1 

Loose Tube 

material 

PBT 

diameter±0.06mm 

1.6 

2.0 

thickness±0.03mm 

0.30 

Number per die 

1 

2 

4 

8 

12 

reinforcing 

plies 

material 

Aramid yarn 

Outer Jacket 

material 

PE 

thickness±0.2mm 

0.6 

0.75 

Optical cable size mm 

5.1 

5.8 

Net weight of optical cable±10kg/km 

22 

28 

weaken 

1550nm 

0.22dB/ km 

bend radius 

dynamic 

20.0 times cable diameter 

static 

15.0 times cable diameter 

temperature range℃) 

Installation temperature 

-40+85 

Transportation & storage 

-40+85 

operating temperature 

-40+85 

 
 
 Optical fiber chromatography
 

serial number

1

2

3

4

5

6

colour

Blue

tangerine

green

brown

grey

white

serial number

7

8

9

10

11

12

colour

red

black

yellow

purple

pink

dark green

 

Loose tube chromatography

serial number

1

colour

white

 
Optical fiber characteristics (ITU-TG.652D)
 

Item 

Unit 

Specification 

G.652D 

Mode field diameter 

1310nm 

um 

9.2± 0.4 

1550nm 

um 

10.4±0.8 

Cladding diameter 

um 

125± 1 

Cladding non-circularity 

% 

1.0 

Core/cladding concentricity error 

um 

0.5 

Coating diameter 

um 

242± 7 

Coating/cladding concentricity error 

um 

12 

Cable cut-off wavelength 

nm 

1260 

  Attenuation Coefficient 

1550nm 

dB/km 

0.22 

1310nm 

dB/km 

0.36 

Proof stress level 

kpsi 

100 

Other parametersmeet the standard. ITU-T G.652D
 
Main mechanical properties and environmentaltests 
 

number 

item 

test mode 

acceptance requirements 

1 

Stretch 

IEC 60794-1-2-E1 

- Load: 600 N(long term) G (short-term) 

When G is less than 1500N, the cable load should be 1500N; when G is between 1500 and 3000N,

 the cable load should be 1500N; when G is greater than 3000N, the cable load should be 3000N. 

- Subject length: 50 m 

- Load duration: 1 minute 

Under long-term tension load: 

- The optical fiber has no obvious strain 

-Noobvious additional attenuation 

Short-term tension load: 

- Additional attenuation:     0.1dB After the test is completed: 

-Nosignificant residual additional attenuation 

- No obvious residual fiber strain 

-No broken fiberand visible cracking of sheath 

- Cable residual strain:      0.08% 

2 

flattening IEC 60794-1-2-E3 

- Load: 

300 N (long term) 1000 N (short term) 

- Load duration: 1 minute 

Under long-term flattening load: 

-Noobvious additional attenuation 

Short-term flattening load: 

- Additional attenuation:     0.1dB After the test is completed: 

-Nosignificant residual additional attenuation 

-No broken fiberand visible cracking of sheath 

3 

impact  IEC 60794-1-E4 

- Impact points: 5 

- Impact times per point :1 

- Impact energy: 4.5 N·m 

After the test is completed: 

-Nosignificant residual additional attenuation 

-No broken fiberand visible cracking of sheath 

4 

alternating bending 

IEC 60794-1-2-E6 

- Core shaft radius: 20 times cable diameter 

- Load: 15kg 

- Subject length: 1 m 

- Bending rate: 2 seconds/time 

- Bending times: 30 times   - Bending Angle: ±90  

After the test is completed: 

-Nosignificant residual additional attenuation 

-No broken fiberand visible cracking of sheath 

5 

reverse  IEC 60794-1-E7 

- Subject length: 1 m 

- Load: 15kg 

- Torsion Angle: ±180° 

- Number of twists: 10 times 

After the test is completed: 

-Nosignificant residual additional attenuation 

-No broken fiberand visible cracking of sheath 

6 

infiltration test IEC 60794-1-F5B 

- Water column height: 1 m 

- Sample length: 3 m 

- Test duration: 24 hours 

There is no water seepage 

7 

High and low temperature cycle test 

IEC 60794-1-F1 

- Temperature step: 

+20℃→-40 +70℃→+20  

- Duration of each temperature point: 12 hours 

- Number of cycles: 2 

-40+70  Additional 

attenuation   0.1 dB/km@1550 nm After the test is completed: 

-Nosignificant residual additional attenuation 

-No broken fiberand visible cracking of sheath 

8 

Drip test  IEC 60794-1-E14 

- Sample length: 30 cm 

- Temperature: 70°C -2°C 

- Test time: 24 hours 

   No drip 

 

Sheath tag    

The printed words on the optical cable should be 1 meter apart and numbered sequentially for length marking.  The initial number of lengths ordered for anycoil shall begin with zero metres.  The accuracy of length marker measurement 

should be controlled within ±1%. Fiber optic cable printing should have the following content  

  1. Name of manufacturer
  2. Cable type
  3. Yearand month of manufacture
  4. each meter of length marked along the cable

Plate with 

Fiber core number 

Wooddisc diameter MM 

Widthof wooden

plate MM 

segment length M

package 

2-12 

500 

 650 

3000(m) 

Clamping plate sealing plate